PSYCHROMETRIC TEST CHAMBERS

Catalogue No.

PSYCHROMETRIC TEST CHAMBERS
  • Description
  • Specification

Supplier

Aralab

|

Catalogue No.

PSYCHROMETRIC TEST CHAMBERS

Temperature and Climatic Testing Chamber

Environmental test rooms, designed for the development and performance evaluation of air conditioners, gas boilers and heat pumps. Usually installed in sets of two environmental chambers, allowing for precise Indoor and Outdoor climatic simulation. Also possible is the integration of third party enthalpic test tunnel.

Designed for the development and performance evaluation of air conditioners, gas boilers and heat pumps.

Simulating “Indoor” and “Outdoor” conditions with temperature, humidity and air flow independently controlled.

Available with ATEX protection features and accessories.

Related test standards:

DIN EN 14511 | DIN EN 14825 | DIN EN 16147

ISO 5151 | ISO 13253

JIS B 8615-1

ASHRAE 41.1 | ASHRAE 41.2 | ASHRAE 41.3 | ASHRAE 41.6

  • Description
  • Specification
Description icon

Environmental test rooms, designed for the development and performance evaluation of air conditioners, gas boilers and heat pumps. Usually installed in sets of two environmental chambers, allowing for precise Indoor and Outdoor climatic simulation. Also possible is the integration of third party enthalpic test tunnel.

Designed for the development and performance evaluation of air conditioners, gas boilers and heat pumps.

Simulating “Indoor” and “Outdoor” conditions with temperature, humidity and air flow independently controlled.

Available with ATEX protection features and accessories.

Related test standards:

DIN EN 14511 | DIN EN 14825 | DIN EN 16147

ISO 5151 | ISO 13253

JIS B 8615-1

ASHRAE 41.1 | ASHRAE 41.2 | ASHRAE 41.3 | ASHRAE 41.6

Specification icon

TECHNICAL SPECIFICATIONS AND PERFORMANCE

Aralab can customize dimensions and performances of the test chambers.

INDOOR ROOM:

TEMPERATURE

+5ºC to +45ºC

HUMIDITY RANGE

20% to 90%

TEMPERATURE PRECISION

± 0,5ºC

TEMPERATURE UNIFORMITY

± 2,0ºc

HUMIDITY PRECISION

± 2%

HUMIDITY UNIFORMITY

± 2%

OUTDOOR ROOM:

TEMPERATURE

-30ºC to +60ºC

RH RANGE

20% to 90%

TEMPERATURE PRECISION

± 0,5ºC

TEMPERATURE UNIFORMITY

± 2,0ºc

HUMIDITY PRECISION

± 2%

HUMIDITY UNIFORMITY

± 2% RH

DIMENSIONS AND DRAWINGS

Aralab can customize dimensions and performances of the test chambers.

Systems can be supplied with enthalpic test tunnel.

Related Product

SciMed (Asia) Pte Ltd | A Member of PHC Group
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.